MIL-C-0052980C(ME)
118.
Delivery lubrication not as specified (see 3.12.5).
Fungus and moisture resistance not as specified (see 3.13).
119.
Identification marking and instruction plates not as specified
120.
(see 3.14).
Treatment and painting not as specified (see 3.16).
121.
Color not as specified (see 3.16).
122.
Camouflage data not provided as specified (see 3.16.1).
123.
Pressure tubing or fitting not rated as specified (see
124.
3.19.3).
V-belts, direct drive, and pulleys not as specified (3.19.4).
125.
Base-mounted compressor not as specified (see 3.21).
126.
Handtruck mounted compressor not as specified (see 3.22) .
127.
128.
Air receiver tank not as specified (see 3.22.1 and 3.24.5).
129.
Wheels and hubs not as specified (see 3.22.2).
Tires and tubes not as specified (see 3.22.3).
130.
Handle and storage rack not as specified (see 3.23.2).
131.
Trailer not as specified (see 3.24).
132.
Cover not as specified (see 3.24.1).
133.
Toolbox not as specified (see 3.24.2).
134.
Cranking access not as specified (see 3.24.3).
135.
Storage rack not as specified (see 3.24.4).
136.
137.
Lifting and tiedown provisions not as specified (see 3.24.6.4
and 3.24.6.5).
138.
Enclosure not as specified (see 3.25.1).
Heater duct connection not as specified (see 3.25.2).
139.
Ducting not as specified (see 3.25.2.1).
140.
Doors, panels and openings not as specified (see 3.25.3).
141.
Fuel tank not as specified (see 3.25.6).
142.
Control panel not as specified (see 3.25.9) .
143.
Fuel and lubricants not as specified (see 3.25.10).
144.
Installation of Government-furnished engine not as specified
145.
(see 3.26.1).
Clutch not as specified (see 3.26.7).
146.
Interchangeability not as specified (see 3.27).
147.
Workmanship not as specified (see 3.28) .
148.
Fabrication not as specified (see 3.28.1).
149.
Welding not as specified (see 3.28.2).
150.
Bolted connections not as specified (see 3.28.3).
151.
Riveted connections not as specified (see 3.28.4).
152.
Machine work not as specified (see 3.28.5) .
153.
4.5.2
Tests.
..
4.5.2.1 Test conditions .
Only the capacity and performance test
and endurance test (see 4.5.2.4 and 4.5.2.5) shall be performed
without. shelter and at the climatic conditions existing at the place
of test.
The compressor shall operate s as specified herein without
maintenance other than the contractor recommended normal schedule
maintenance as established by a maintenance schedule prepared and
submitted by the contractor prior to test.
The compressor shall be
lubricated with military oils and greases.
Oils shall be those
designated for use at the ambient temperature at the place of test.
A first article test log similar to figure 3 shall be furnished
25
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business