MIL-C-0052980C(ME)
The first article compressor shall be
4.3.1 Examination.
Presence of one or more defects
examined as specified in 4.5.1.
shall be cause for rejection.
4.3.2 Tests.
The first article compressor shall be tested as
specified in 4.5.2.1 through 4.5.2.21 as applicable for the class
Failure of any test shall be cause for
compressor to be furnished.
rejection. A first article test log (see figure 3) shall be
For diesel-engine-driven compressors, JP-8 shall be used
furnished.
for all first article tests.
4.4
Qua lity conformance inspection.
4.4.1 E x a m i n a t i o n . Each compressor shall be examined in
Presence of one or more defects shall be
accordance with 4.5.1.
cause for rejection.
4.4.2
Tests.
4.4.2.1 Individual.
Each compressor shall be tested as specified
Failure of a test shall be cause for
in 4.5.2.2 and 4.5.2.22.
rejection.
For diesel-engine-driven compressors, JP-8 or DF-2 can
be used for the quality conformance tests.
Inspection procedure.
4.5
The compressor shall be examined for the
4.5.1 Examination.
following defects:
101.
Material not as specified (see 3.4) .
102.
Materials not resistant to corrosion and deterioration, or
treated to be resistant to corrosion and deterioration of the
applicable storage and operating environments (see 3.4.1).
Dissimilar metals as defined in MIL-STD-889 are not
103.
effectively insulated from each other (see 3.4.2).
Used, rebuilt or remanufactured components, pieces, or parts
104.
incorporated in the compressor (see 3.5) .
Safety devices or guards missing or not as specified
105.
(see 3.7.1).
Ease of maintenance not as specified as defined in ANSI B19.1
106.
(see 3.7.1).
Human factors engineering not as specified (see 3.7.2).
107.
Noise sign not as specified (see 3.7.3).
108.
Noise level not as specified (see 3.7.3).
109.
Parts, special tools, and items to be furnished with
110.
compressor missing or not as specified (see 3.8.2).
Air hose not as specified (see 3.9) .
111.
Intake air not as specified (see 3.10).
112.
113.
Lubrication not as specified (see 3.12).
114.
Lubricants not as specified (see 3.12.1).
115.
Lubrication fittings not as specified (see 3.12.2).
116.
Pressure-release device not as specified (see 3.12.3).
117.
Enclosures with integral reservoir or lubricant not as
specified (see 3.12.4).